Souhrn technické specifikace
-
Sampling probe compatibility
Raman Rxn-10 probe
Oblast použití
Paired with the Rxn-10 probehead, Raman non-contact optics provide contact-free Raman measurements of samples either directly or through sight glass or translucent packaging. Available with a range of working distances, these highly versatile optics are the perfect choice for use with solids or turbid media. They are also well suited for delicate or corrosive samples when sample contamination or damage to optical components is a concern.
Pharmaceutical: Drug product manufacturing
Chemical: Polymer solids (pellets, films, or powders)
Food & Beverage: Meat or fish quality
Raw material identification
Formulation optimization
Výhody
Range of working distances for remote measurements either directly or through sight glass and translucent packaging
Highly versatile – measuring films to pellets to powders
Accurate measurement of static or moving samples
Contact-free analysis of delicate or corrosive samples
Výběr produktů z řady Extended
-
Špičkové produkty
- Vysoce funkční a přesto jednoduché
Technická výkonnost
Jednoduchost
-
Jednoduché produkty
- Jednoduchý výběr, instalace i provoz
Technická výkonnost
Jednoduchost
-
Standardní produkty
- Spolehlivé, robustní a nenáročné na údržbu
Technická výkonnost
Jednoduchost
-
Špičkové produkty
- Vysoce funkční a přesto jednoduché
Technická výkonnost
Jednoduchost
-
Specializované produkty
- Navrženo pro těžké aplikace
Technická výkonnost
Jednoduchost
Dle konkrétního produktu
Výběr produktů FLEX | Technická výkonnost | Jednoduchost |
---|---|---|
Výběr produktů z řady Fundamental Pro jednoduché aplikace |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Lean Efektivně pokrývejte běžné procesní požadavky |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Extended Optimalizujte své procesy inovativními technologiemi |
Technická výkonnost
|
Jednoduchost
|
Výběr produktů z řady Xpert Zvládněte i ty nejtěžší aplikace |
Technická výkonnost
|
Jednoduchost
Dle konkrétního produktu |
-
-
Technické informace (TI)
Accessory optics for the Rxn-10 probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN CS 31/05/202303/08/2022Jazyk:
English
Verze:
31/05/2023
Velikost souboru:
467.9 KB
Název souboru:
TI01635CEN_0322.pdf
-
-
-
Technické informace (TI)
Rxn-10 Raman Spectroscopic Probe Technical Information
System design and specifications
for the Raman Rxn-10 probeEN CS 31/05/2023Jazyk:
English
Verze:
31/05/2023
Velikost souboru:
423 KB
Název souboru:
TI01629CEN_0322.pdf
-
-
-
Návod k obsluze (BA)
Accessory optics for the Rxn-10 probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN CS 31/05/202303/08/2022Jazyk:
English
Verze:
31/05/2023
Velikost souboru:
1.8 MB
Název souboru:
BA02171CEN_0322.pdf
-
-
-
Návod k obsluze (BA)
Rxn-10 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probeEN CS 31/05/2023Jazyk:
English
Verze:
31/05/2023
Velikost souboru:
1.2 MB
Název souboru:
BA02160CEN_0322.pdf
-
-
-
Krátká instrukce (KA)
Rxn-10 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
Jazyk:
English
Verze:
31/05/2023
Velikost souboru:
895.3 KB
Název souboru:
KA01546CEN_0322.pdf
-
-
-
Krátká instrukce (KA)
Accessory optics for the Rxn-10 probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN CS 31/05/202303/08/2022Jazyk:
English
Verze:
31/05/2023
Velikost souboru:
1 MB
Název souboru:
KA01551CEN_0322.pdf
-
-
-
PU (publikace)
ライフサイエンス産業向けのラマンアプリケーションガイド -ライフサイエンスのための信頼できる組成分析
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。Jazyk:
Japanese
Verze:
02/08/2024
Velikost souboru:
1.4 MB
Název souboru:
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf
-
-
-
PU (publikace)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Jazyk:
English
Verze:
19/04/2022
Velikost souboru:
1.1 MB
Název souboru:
PU01447CEN_0222.pdf
-
-
-
Kompetenční brožura (CP)
Raman spectroscopy food & beverage application guide - Trusted technology for composition analysis in a laboratory or process environment
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).Jazyk:
English
Verze:
17/02/2022
Velikost souboru:
859 KB
Název souboru:
CP01489CEN_0122.pdf
-
-
-
Inovace (IN)
Raman spectrographic probes - Robust optical measurement of chemical composition
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.Jazyk:
English
Verze:
26/10/2021
Velikost souboru:
4.9 MB
Název souboru:
IN01225CEN_0121.pdf
-