Specs at a glance
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
t50 = 3 s
t90 = 6 s -
Max. process pressure (static)
at 20°C: up to 75 bar (depending on the process connection)
-
Operating temperature range
PT 100:
-200 °C ...600 °C
(-328 °F ...1.112 °F) -
Max. immersion length on request
up to 10.000,00 mm (393,70'')
Field of application
The RTD cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.
The resistance thermometer is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid media like air, water, oil and others.
Benefits
High flexibility through user-specific insertion lengths and variable process connections
Fast response time
Single or double Pt100 sensor of accuracy class A, B, or AA as per IEC 60751
Types of protection for use in hazardous locations: Intrinsic safety (Ex ia) and non-sparking (Ex nA)
-
Marine approval
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
TI TST310
Resistance thermometer
EN 31/03/202324/07/201823/09/201101/03/201001/04/2001Language:
English
Version:
31/03/2023
File size:
825 KB
File name:
TI00085TEN_0323-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA iTHERM TM211, TPx100, TSx310
RTD/TC inserts and cable thermometers
ATEX/IECEx:
Ex ia IIC T6 Ga
Ex ia IIC T6 Ga/Gb
Ex ia IIIC Txxx °C DaEN 30/03/202318/07/202210/07/201928/11/201628/11/2012Language:
English
Version:
30/03/2023
File size:
456.3 KB
File name:
XA00100REN_1823-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA TR1x, TR4x, TR88, TR6x, TC1x, TC88, TEC420, TC6x
RTD/TC thermometers
ATEX/IECEx:
Ex ia IIC T6 Ga
Ex ia IIC T6 Ga/Gb
Ex ia IIIC Txxx °C Da
Ex ia IIIC Txxx °C DbEN 28/03/202320/12/202103/05/201628/11/201201/06/2009Language:
English
Version:
28/03/2023
File size:
450.8 KB
File name:
XA00072REN_1623-00.pdf
-
-
-
Ex Safety Instruction (XA)
Safety instructions
Safety instructions
Language:
English
Version:
09/08/2022
File size:
1 MB
File name:
XA02908T_01.22.pdf
-
-
-
Ex Safety Instruction (XA)
XA TPx100, TSx310,
RTD/TC inserts and cable thermometers
0Ех ia IIC T6…T1 Ga Х
Ех ia IIIC 85 °C…450 °C Da ХEN 15/07/202401/11/202113/04/202019/05/2016Language:
English
Version:
15/07/2024
File size:
451.6 KB
File name:
XA01421TEN_0424-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA TRxx, TCxx
RTD/TC thermometers
Ga/Gb Ех ia IIC T6…T1 Х
Ех ia IIIC T85 °C…T450 °C Da/Db ХEN 17/07/202410/03/202002/11/2016Language:
English
Version:
17/07/2024
File size:
453.6 KB
File name:
XA01459TEN_0324-00.pdf
-
-
-
Ex Safety Instruction (XA)
Safety instructions ATEX II1GD or II 1/2 GD
RTD / TC inserts and cable thermometers
Omniset TPR100, TPC100, TSx310EN 01/06/2009Language:
English
Version:
01/06/2009
File size:
1.8 MB
File name:
XA087ra3_0609.pdf
-
-
-
Ex Safety Instruction (XA)
XA TRxx, TCxx, TEC420, TS111, TM211, TM41x, TPx100, TSx310, TM1xx
RTD/TC thermometers
ATEX:
Ex nA IIC T6 Gc
Ex ec IIC Txxx°C Gc
Ex tc IIIC Txxx°C DcEN 20/11/202313/12/202214/03/202223/05/201904/08/2017Language:
English
Version:
20/11/2023
File size:
452.6 KB
File name:
XA00044REN_2023-00.pdf
-
-
-
Ex Safety Instruction (XA)
TST310 Safety instructions
Proof of intrinsic safety
Control DrawingLanguage:
English
Version:
28/05/2013
File size:
136.6 KB
File name:
XA01168TEN_0113.pdf
-
-
-
Special Documentation (SD)
Device viewer
Technical documentation in other languages
Language:
English
Version:
14/07/2021
File size:
478.5 KB
File name:
SD02429R09EN_0121.pdf
-