Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Prosonic FMU42 - Ultrasonic measurement

Ultrasonic measurement
Time-of-Flight
Prosonic FMU42

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m

FMU42
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN80, ASME 3", JIS 10K 80
    DN100,ASME 4", JIS 10K 100
    Mounting bracket

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    4...20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IEC, INMETRO, NEPSI

  • Application limits

    Foam / high turbulence possible:
    FMU44/FDU92
    Fast filling and discharging
    rate:
    FMU90 + FDU9x
    Level limit detection
    FMU90 + FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4 mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN80, ASME 3", JIS 10K 80
    DN100,ASME 4", JIS 10K 100
    Mounting bracket

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    4...20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IEC, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram